Single line centralized lubricating systems are divided into the following four major types:
(1) Manually operated pump system
(2) Motor driven pump system
(3) Motor driven multi-zone system
(4) Oil spray system
The following table summarizes the component equipment of each system and their combinations. (For details, refer to the Equipment Manual.)
List of systems
| Drive system |
Format | Pump | System pressure (MPa) |
Distributing valve | Number of lubricating ports (max.) |
Electric control panel type |
Remarks | ||||
| Discharge quantity (cm 3 /min) |
Tank capacity (L) |
Electric motor output (kw) |
Format | Discharge quantity (cm 3 /stroke) |
|||||||
| 1500min
-1 50Hz |
1800min
-1
60Hz |
||||||||||
| Manually operated | KM-42AK | 3.5 cm 3 /stroke | 2 | - | 21 | MJN M MX |
0.082 to 0.492 0.164 to 1.148 0.41 to 4.92 |
80 | - | For grease | |
| KM-52AK | 4 | ||||||||||
| KM-32AKP-10 | 1.6 | ||||||||||
| KM-52AKP-10 | 3 | ||||||||||
| KM-3BKP | 7 cm 3 /stroke | 1.6 | 10 | For oil | |||||||
| KM-5BKP | 3 | ||||||||||
| Motor driven | AKA-104AK | 30 | 36 | 4 | 0.1 | 21 | 200 | EK | For grease | ||
| AKA-108AK | 8 | ||||||||||
| AKA-115AK | 15 | ||||||||||
| AKA-125AK | 25 | ||||||||||
| AKA-104AKP | 4 | ||||||||||
| AKA-108AKP | 8 | ||||||||||
| AKA-104BKP | 30 | 36 | 4 | 10 | For oil | ||||||
| AKA-108BKP | 8 | ||||||||||
| LPP series | 29 to 83 | 35 to 100 | Pail can | 0.09 | 21 | 200 | For grease | ||||
| LBP series | 75 to 316 | 90 to 380 | Drum can | 0.2 to 0.4 | 500 | ||||||
| MB | 316 | 380 | Drum can | 0.4 | *2000 | *1 | |||||
(Article)
• The number of lubricating ports in the above table indicate values at 0°C with the NLGI consistency #1 grease.
Note, however, that 2,000 ports marked with an asterisk ‘*’ are limited to a multi-zone system.
(This varies according to the brand of grease, ambient temperature, and pipe diameter.)
• Replenish the pumps and tank with grease by using a grease filling pump via the replenishing port. (excluding pail can pumps and drum can pumps)
•Standard voltage of electric motor
200 V AC 50/60 HZ, 220 V AC 60 HZ
400 V AC 50/60 HZ, 440 V AC 60 HZ
• Consult with us regarding different voltages.
• *1 Consult with us regarding the electric control panel.